Published On: 24. November 20264.8 min read

Flare gas monitoring only delivers reliable data if the entire analytical chain fits together: flare gas is wet, contaminated and highly variable in composition, and the sampling points are almost always in hazardous areas. What matters is an Ex-certified heated gas sampling probe, a heated sample line free of cold spots at 150 to 180 °C and suitable sample gas conditioning. This is the conclusion of the case study by Harald Mahler (PSG) published in International Environmental Technology (IET), May/June 2026 issue.

Read the full case study: case study as PDF (3 pages) or online on Envirotech Online (IET). This article summarizes its key points.

Why is flare gas monitored continuously?

Flare gas is monitored because regulators worldwide limit emissions from flares and require ongoing measurements – usually at least four analyses per hour. In the USA, the rules include the Refinery Sector Rule (40 CFR Part 63 Subpart CC), NSPS Subpart Ja and the Texas HRVOC rules; methane is covered by 40 CFR Part 60 Subpart OOOOb/c. In Europe, the EU Emissions Trading System with national implementations such as the German TEHG and the UK EEMS applies, as does the EU Methane Regulation. Pressure is rising: according to the World Bank, global flare volumes rose to 167 billion cubic meters in 2025, the highest level since 2019, while the goal of zero routine flaring by 2030 remains.

Which parameters does a flare gas monitoring system measure?

A flare gas monitoring system pursues three analytical objectives:

  • Heating value: nitrogen and hydrocarbons from methane (C1) to butanes and heavier components (C4+) – the heating value must be high enough for complete combustion.
  • Sulfur compounds: hydrogen sulfide (H₂S) and total sulfur, to limit SOₓ emissions.
  • Reactive hydrocarbons: olefins and volatile organic compounds (VOCs) that contribute to ozone formation.

Depending on the regulation, six to fourteen or more components must be measured, from trace sulfur at ppm level to hydrocarbons close to 100 %. Flow, pressure and temperature are added to calculate the emission load. Process gas chromatographs and calorimeters are the established analyzers; mass spectrometry and FTIR are gaining ground.

Why do flare gas measurements usually fail at sampling?

Flare gas measurements usually fail at sampling because the gas changes its composition on the way to the analyzer. Gases from pressure relief, start-up and shutdown or routine venting are inhomogeneous, humid and often contaminated. If the sample cools down anywhere, water and heavy hydrocarbons condense, the phases separate, and the analyzer measures a sample that no longer matches the flare gas. A single cold spot at a connection is enough – regardless of how good the analyzer is.

What does Ex-compliant sampling for flare gas monitoring look like?

Ex-compliant sampling for flare gas monitoring consists of three matched stages, all approved for hazardous areas:

  • Gas sampling probe: The PSG Process Probe ATEX 180 is self-limiting heated to 180 °C, even at −40 °C ambient temperature, and needs no temperature limiter. Its active filter surface of 212 cm² is the largest on the market; single or dual stage back purging keeps it clean at dust loads of up to 40 or 280 g/m³.
  • Heated sample line: 150 to 180 °C is typical, so that no acid dew point is undercut. The PSG Process Extruded ATEX is self-regulating, designed for Ex zones 1 and 2, available in one piece of up to 300 m and can be cut to length on site. DIN EN IEC 60079-0 requires the entire line to be assessed, including electrostatic discharge; conductive, grounded jackets control this risk.
  • Sample gas conditioning: If no analyzer shelter is available, the cooler, dryer and pump must themselves be Ex-certified. Compressor coolers of the PSG Process Cooler BCR ATEX series offer one to four gas paths. Nafion® membrane dryers operate on instrument air only and have no electrical components.

Our “Flare Gas Monitoring” checklist summarizes all planning points from probe to analyzer.

How does the Livitron group work together at the flare?

The Livitron group covers the flare from ignition and flame monitoring to gas analysis. PSG belongs to the group, as do TESI Igniters, BFI Automation and Mems. TESI Igniters builds high-energy ignition systems for ground flares, elevated flares and offshore flares that deliver a strong spark even through ignition cables of up to 500 m. BFI Automation supplies flame monitoring for safe combustion, PSG the sampling and sample gas conditioning for flare gas analysis. At ADIPEC 2026 in Abu Dhabi, TESI Igniters, BFI Automation and PSG presented their solutions together at booth 2257.

Frequently asked questions

How often does flare gas have to be analyzed? Most regulations require continuous or near-continuous measurement with at least four analyses per hour. The heated sample line should therefore be short and the sample flow fast enough to meet the analysis cycle.

Does the ATEX certification cover the entire heated line? With conventional lines, only the heating cable is certified, and the installer is responsible for the finished assembly. PSG’s patented Ex² and Ex³ extruded lines are certified as a complete assembly (website FAQ).

Can flare gas be dried without a condensate cooler? Yes, with Nafion® membrane dryers: they remove water as vapor without losing components in condensate. Whether the method fits depends on the process parameters and must be checked for each application.

Support from PSG

PSG supplies the complete sampling chain for hazardous areas from a single source – probe, line, cooler and, on request, the complete analyzer system. Read the full case study “Integrated flare gas monitoring” as a PDF or on Envirotech Online (IET).

Talk to us: Robin Liebelt, Sales Engineer at PSG, will advise you on your sampling point – book a meeting or contact us.

The information in this article is general guidance and does not replace the operating instructions of the equipment used.

A practical gas analysis topic every month

Subscribe to the PSG newsletter – with checklists and decision aids for your sampling point.